What it does
Timber Pole Retaining Wall checks round timber poles set in concrete-filled bored holes with timber lagging, for gravity and earthquake cases. It checks the pole embedment, the poles above and below ground, the lagging and the timber treatment. The calculator's own User guide explains each input and check in detail.
What you enter
- The retained height, the pole embedment, spacing and hole diameter.
- The retained and foundation soil properties, the surcharge and the earthquake inputs.
- The pole size and strength, the lagging and the timber treatment.

What you get
- A pass or fail result with the governing check and combination.
- Embedment, pole, lagging and durability checks with their clauses.
- A section and plan of the wall and diagrams of the load, shear and moment along the pole, an A4 report, and a project file or account project that keeps the inputs.
Scope
- Cantilever poles in concrete-filled holes, with level ground in front.
- Not checked: global slope stability, settlement, drainage and the concrete encasement.